Operation Manual Model : SM-100 Edition Month Year 1st December 2004 2nd December 2005 3rd February 2006 SHANGHAI TERAOKA ELECTRONIC CO.,LTD
3.16.3 Programming Parameter Of Print Items ... 80 3.16.4 Free Format Entry ...
SM – 100 Operation Manual 88 3.16.7 Sample of program a format by modifying the existing format You can create your desired label format by copying
SM – 100 Operation Manual 89 Following is the example on how to customize standard format T8 to your needs. E.g. Add an ingredient text and remove t
SM – 100 Operation Manual 90 OPERATION DISPLAY REMARK PT kg $/kg $ [*][*][1][5] S12.5 COMM 15 HT MM Enter TTL Height setting mode, change the height
SM – 100 Operation Manual 91 3.17 Place File PLACE file is used for programming a short text describing the place of production. The number of Char
SM – 100 Operation Manual 92 3.18 Machine Setting OPERATION DISPLAY REMARK PT kg $/kg $ S1 → PLU FILE Enter S mode. [1][6][*] S16.0 RATE 0.00 DISC
SM – 100 Operation Manual 93 3.19 Logo File Logo is the trademark of the shop, which will be printed in Label or Receipt. Logo will be printed on t
SM – 100 Operation Manual 94 3.19.2 Program Display & Keys Function Program Display for Logo Set Up The following display appears when enterin
SM – 100 Operation Manual 95 3.19.3 Programming Order 1) After filling a section, programming status (the position of the cursor) moves to the next
SM – 100 Operation Manual 96 3.19.5 Delete Logo File At Logo programming mode, enter existing Logo Number (Ex. 1) to be deleted. OPERATION DISPLAY
SM – 100 Operation Manual 97 3.20 Tax File This function enables you to program consumption tax rate included or excluded in the price. Up to 10 Ta
4.3.2 Digital tare Subtraction ... 106 4.
SM – 100 Operation Manual 98 3.20.2 Delete Tax File When the Tax Number linked to the existing Main Group File or PLU File, the Tax Number cannot
SM – 100 Operation Manual 99 3.21 Scroll Message File Maximum 100 characters can be programmed for each scroll message and up to 9-scroll message d
SM – 100 Operation Manual 100 3.22 Scroll Sequence File Scroll Sequence # 1 to # 3 is available. Each scroll sequence consists of up to three kinds
SM – 100 Operation Manual 101 3.22.2 Enable or Disable Scroll Sequence File This Function is used to enable the programmed Scroll Message data by S
SM – 100 Operation Manual 102 3.22.3 Delete Scroll Sequence Number When the Scroll Sequence Number to be deleted is in Used, it can’t be deleted. A
SM – 100 Operation Manual 103 3.23 ASCII Character Input Method Insert Key-sheet for ASCII Character Input: (For standard version) ?/?¨ ¦/¨ ¦+? <
SM – 100 Operation Manual 104 3.24 ASCII Code Input Method ASCII Code Input Method is another kind of input method for ASCII character entry. [CODE
SM – 100 Operation Manual 105 4. REGISTRATION MODE 4.1 ON/OFF
SM – 100 Operation Manual 106 4.3 Tare Subtraction 4.3.1 One touch Tare Subtraction
SM – 100 Operation Manual 107 4.4 PLU Call Up There are three ways to cal up programmed PLU: Manual PLU Call Up By press assigns to the preset
5.2.7 Clerk Report ...
SM – 100 Operation Manual 108 4.5 Fix Operation 4.5.1 Fix Tare by FIX Key
SM – 100 Operation Manual 109 4.6 Operation Mode Change
SM – 100 Operation Manual 110 4.7 Item Label Printing in Manual Mode You can use this operation to print out item labels for a PLU or Non-PLU of We
SM – 100 Operation Manual 111 4.7.2 Label Printing for NON-PLU Item It is possible to print item label for Non-PLU Item at Manual Mode. The Non-PLU
SM – 100 Operation Manual 112 4.8 Total Label Printing in Manual Mode This operation is used for printing total label in Manual Mode. 4.8.1 Sales
SM – 100 Operation Manual 113 4.8.2 [PRICE DISCOUNT] Function Key in Add Mode This function key is used to get the desirable discounted total price
SM – 100 Operation Manual 114 4.9 Data Correction The data correction during accumulating operation is to correct sales transaction data when custom
SM – 100 Operation Manual 115 4.9.2 Void by Item Correction This function is to void the specified transaction during an accumulating operation. Op
SM – 100 Operation Manual 116 4.10 Item Label Printing in Pre-pack Mode Pre-pack Mode can be switched from Manual mode by pressing [AUTO] key. In t
SM – 100 Operation Manual 117 4.10.2 Item Label Issue for NON-PLU Item It is possible to print item label for Non-PLU Item at Pre-pack Mode. The No
SM – 100 Operation Manual 1 1. GENERAL INFORMATION 1.1 Overall View Bench Type Pole Type
SM – 100 Operation Manual 118 5. READ REPORT MODE 5.1 Report Factor Select Whether to use the following report print factors depends on the type of
SM – 100 Operation Manual 119
SM – 100 Operation Manual 120 5.2.1 Main Group Report Printing report order for MAIN GROUP Daily/Term Read Report: For example: MAIN GROUP LOWER
SM – 100 Operation Manual 121 OPERATION DISPLAY REMARK PT kg $/kg $ [3][*] X2.4 3 ED NUM Enter ending PLU Number. (Ex.999996) [9][9][9][9][9][6][*]
SM – 100 Operation Manual 122 5.2.4 Sales Report Printing report order for SALES Daily/Term Read Report: OPERATION DISPLAY REMARK PT kg $/kg $ Ente
SM – 100 Operation Manual 123 3) Rank C includes PLUs whose accumulated share is between 95% ~ 100%. *Even if the accumulated share exceeds 95%, th
SM – 100 Operation Manual 124 5.2.8 Pre-pack Report On Pre-pack Report, Total data of Prepack labels (Such as total price, total quantity, etc) can
SM – 100 Operation Manual 125 5.2.9 Tax Report Tax report is used to print out the Tax total data such as Tax Type, Tax rate, Amount Including Tax,
SM – 100 Operation Manual 126 6. RESET REPORT MODE 6.1. Reset Report 6.1.1 Sales Daily / Monthly/Term Reset Report OPERATION DISPLAY REMARK PT kg $
SM – 100 Operation Manual 2 Elevated Type
SM – 100 Operation Manual 3 1.2 Display Panel 1.3 Key Panel Bench / Pole Type Elevated Type
SM – 100 Operation Manual 4 1.4 Features Digital printing scale consists of electronic cash registers function and label printing function. H
SM – 100 Operation Manual 5 1.5.2 Operating Conditions Power Source : AC 176V ~ 264V, 47~63Hz. Operating Temperature : -10 C ~ +40 C.
SM – 100 Operation Manual 6 1.6 Key Functions ON/OFF KEY Turn display "ON" or "OFF". PRESET KEY P1 ~ P74 Set up or call ei
SM – 100 Operation Manual 7 MULTIPLLE KEY X Register the number of Non-Weight products. Select programming item such as PLU data, Shop Name in
SM – 100 Operation Manual 8 MODE SELECT KEY Five Modes can be selected using this key. Indicator R - REGISTRATION MODE (All the sales transact
SM – 100 Operation Manual 9 2. SETUP 2.1 Mode Change OPERATION DISPLAY REMARK PT kg $/kg $ 0.000 0.000 0.00 0.00 Weight mode.Lamp R turns on. [MO
SM – 100 Operation Manual 10 2.2 Specification Setting 2.2.1 Specification Entry(141) Before setting 141, please enter Z mode. OPERATION DISPLAY REM
SM – 100 Operation Manual 11 2.2.2 Specification List Customer SPEC Setting-(141) SPEC NO. SPECIFICATION DESCRIPTION SM-100 00 Item Barcode
SM – 100 Operation Manual 12 08 Left Side Data of Total Label 0 Scale No. 3 Clerk No. 1 Last Accumulated Item Code 4 Fixed No. 2 Recei
SM – 100 Operation Manual 13 23 Manual Price Entry for Printing or Accumulating 0 Allow 1 Inhibit 24 Default Label Format for I
SM – 100 Operation Manual 14 32 CDV Modulus 0 Modulus 10 1 Modulus 11 For SF only. Effective when SPEC30 and 31 = 1. 33 On Spot Correcti
SM – 100 Operation Manual 15 48 Setting of Scale Number Enter value from range 0 to 999 999 49 Type of Client / Server Interfac
SM – 100 Operation Manual 16 60 SIO (RS-232C Port) Select Job 0 No Operation 3 Point ‘N’ Shop Apply for both RS-232C and RS-485 ports set
SM – 100 Operation Manual 17 76 Quantity Set Function Key Enable 0 Allow 1 Inhibit 77 Price Change Function Key Enable 0 Allow
OPERATIONAL MENU TREE Registration Mode ( R Mode ) Report Print Mode ( X Mode ) X1.1 Read Main Group Daily
SM – 100 Operation Manual 18 92 Printer Speed for Label 0 Slow 2 High 1 Normal Printer Strode 0 Single 2 Not Used 1 Double
SM – 100 Operation Manual 19 108 Fixed Unit Price Percentage Markdown Function Key Enable 0 Allow 1 Inhibit 109 Source of Sell b
SM – 100 Operation Manual 20 124 PLU Unit Price after Discount 0 Unit Price after Discount 1 Unit Price Discount Amount 125 Posi
SM – 100 Operation Manual 21 141 Year Format 0 YY 1 YYYY 142 Selection of Day Display for Sell by Date 0 Disable 1 Enable 14
SM – 100 Operation Manual 22 160 Twisted Pair Cable for Ethernet 0 Shield 1 Unshielded Not in used. 161 Discount Label Format 0
SM – 100 Operation Manual 23 178 Unit Price Override per PLU 0 No 1 Yes 179 Black Bar Sensing Label 0 Normal 1 Black Bar Sensin
SM – 100 Operation Manual 24 195 Weight Print for Non-weigh Item 0 No 1 Yes 196 Scale File 0 Disable 1 Enable 197 Print Form
SM – 100 Operation Manual 25 212 Department Number for Pick ‘N’ Pay Enter a value between 1 to 99 For SF only. 213 Flag Code Fun
SM – 100 Operation Manual 26 228 Individual PLU Total Transaction 0 No 1 Yes 229 Preset Key Group 0 Disable 1 Enable Effective
SM – 100 Operation Manual 27 246 Print First and Check Digits Outside Barcode 0 No 1 Yes 247 Print Packed date 0 Manual and Pr
S1 PLU File S1.0 Enter PLU No. S1.1 Unit Pri
SM – 100 Operation Manual 28 262 Selection of Receipt / Label 0 Label 1 Receipt Always set to 1 for SM-200. 263 FSD Net Value Mi
SM – 100 Operation Manual 29 277 Real Time Buffer 0 No 4 5 Days 1 2 Days 5 6 Days 2 3 Days 6 7 Days 3 4 Days 7 Unlimited 278
SM – 100 Operation Manual 30 293 SM-200 Power Save Timeout 0 3 Min 2 10 Min 1 5 Min 3 2 Min PLU Scrolling Message Display Interval
SM – 100 Operation Manual 31 308 SM-500 2nd Receipt Printer 0 Disable 1 Enable 309 Praxis Function 0 Disable 1 Enable For DE
SM – 100 Operation Manual 32 326 ON/Off Key 0 Disable 1 Enable 327 SM300 Print Control 0 Disable 1 Enable 328 TU 9 Digit
SM – 100 Operation Manual 33 343 Clear Key in Prepack 0 Enable 1 Disable 344 Print Pack Date 0 Yes 1 No 400 Auto Pow
SM – 100 Operation Manual 34 414 In-Store Barcode for Barcode Scanner Enter 0 F1F2 CCCCCC TTTT CD 5 F1F2 CCCCC XCD TTTT CD #1: F1F2 - 20~
SM – 100 Operation Manual 35 430 Items on PLU / Main Group / Dept / Tax Report 0 Registered Items 1 All Items 431 Eliminate Ven
SM – 100 Operation Manual 36 2.3 Password Setting 2.3.1 Procedures of Password Setting OPERATION DISPLAY REMARK PT kg $/kg $ Z1.0 RESET SALES DAI
SM – 100 Operation Manual 37 2.3.2 Password Using {Hypothesis: PWD X: 1111; PWD S: No Set; PWD P: 1234} OPERATION DISPLAY REMARK PT kg $/kg $ 0.00
S12 Free Format S12.0 Free Format Number S12.1 Label W
SM – 100 Operation Manual 38 2.4 Clear Files This function is used to clear files in Memory. OPERATION DISPLAY REMARK PT kg $/kg $ Z1.0 RESET SALE
SM – 100 Operation Manual 39 3. PROGRAM MODE 3.1 Programmable Files In Programming Mode, there are two ways to select the Programming File by usin
SM – 100 Operation Manual 40 3.2 General Explanation DEPARTMENT, MAIN GROUP and PLU files are connected as shown below. By the following linking me
SM – 100 Operation Manual 41 3.3 Department Files Department file is used for categorizing Main Groups. Department Number between 1 ~ 99 are availa
SM – 100 Operation Manual 42 3.3.2 Delete Department File OPERATION DISPLAY REMARK PT kg $/kg $ [MODE][MODE] [MODE] S1 → PLU FILE Enter S mode. Lam
SM – 100 Operation Manual 43 3.4 Main Group Files Main Group is the middle category and can be assigned to a Department. The Main Group file is use
SM – 100 Operation Manual 44 (No.997 is default No. for PLU programming, and the PLUs which are not linked to any Main Group No. are assigned to No.
SM – 100 Operation Manual 45 3.5 Program / Skip Item Data Unnecessary PLU parameters will be skipped automatically due to auto-skip function, it is
SM – 100 Operation Manual 46 No. Display Parameter Symbol 35 [DAY WK] 35. Discount day of the week DAYWK 36 [ADD-ON] 36. EAN 5 Digit ADD-ON ADDON 3
SM – 100 Operation Manual 47 3.6 PLU Programming The following items can be programmed in PLU PROGRAMMING mode. The format chosen for the PLU will
S19 PLU Item Label Format 1 [LABFR1] Label Format 2 [LABFR2]
SM – 100 Operation Manual 48 Step PLU File (weighing Item) Remarks S1.23 Select to print Key-In data or actual time * If S1.21 select CLOCK TIME, Ke
SM – 100 Operation Manual 49 Non-Weighing Item Step PLU File (Non-weighing Item) Remarks S1.0 PLU No. S1.1 Unit Price (6 digits) S1.2 Label Form
SM – 100 Operation Manual 50 Step PLU File (Non-weighing Item) Remarks S1.30 The 1st target of volume discount * If No Volume discount is selected,
SM – 100 Operation Manual 51 3.6.1 Program PLU File(weighing item) PLU data(weighing item) is programmed by following procedure as below. If the se
SM – 100 Operation Manual 52 OPERATION DISPLAY REMARK PT kg $/kg $ [1][0][0][1][0] [*] S1.9 PLU 00000 EX CODE No appended item code of PLU 100. [*]
SM – 100 Operation Manual 53 OPERATION DISPLAY REMARK PT kg $/kg $ [1][0][0] [*] S1.29 PLU NO DISCONT 6 kinds discount type can be selected b
SM – 100 Operation Manual 54 Note3: The 2 digits after "C" in Weight display shows the line of the commodity name, and the next 2 digits i
SM – 100 Operation Manual 55 OPERATION DISPLAY REMARK PT kg $/kg $ [C][A][K][E] [*] S1.4 C02.01 S1 A 100 Enter the 2nd line of comm ddity nam
SM – 100 Operation Manual 56 OPERATION DISPLAY REMARK PT kg $/kg $ [*] S1.20 PLU NPRINT PACK DT Press [<<] or [>>] key to change w
SM – 100 Operation Manual 57 OPERATION DISPLAY REMARK PT kg $/kg $ [1][1][0][1][0][4] [*] S1.38 PLU 0000 ED TIME Set discount end time.(Ex. 09:00) [
PLU Linked Text Field [PLUTEX] Reset Report Mode ( Z Mode ) Z1.0 R
SM – 100 Operation Manual 58 3.6.3 PLU [COPY] Function The programmed PLU data can be easily copied into a new PLU. The function is very useful to
SM – 100 Operation Manual 59 3.6.4 Delete PLU File OPERATION DISPLAY REMARK PT kg $/kg $ [MODE][MODE] [MODE] S1 → PLU FILE Enter S mode. Lamp S turn
SM – 100 Operation Manual 60 3.6.5 Volume Discount & Mark Down print function Volume Discount function is used to set up special price during a
SM – 100 Operation Manual 61 Mark Down Print Function (How to print discount price) Mark Down Print function is used to print the discount price as
SM – 100 Operation Manual 62 3.7 Memory Status The function is used for checking the number of existing PLU and remaining programmable PLU. OPERATI
SM – 100 Operation Manual 63 3.8 Key Assignment The Preset keys can be used for assignment of PLUs and Function keys to speed up the operation in R
SM – 100 Operation Manual 64 OPERATION DISPLAY REMARK PT kg $/kg $ [*] S4.1 VR AS 0 NO SET Enter Vender Key assignment status. [*] S4.2 FN AS 0 CLEA
SM – 100 Operation Manual 65 3.9 Shop Name File Shop Name data will be printed on Label or Receipt can be programmed in this file. The maximum numb
SM – 100 Operation Manual 66 3.9.2 Delete Shop Name File At Shop Name programming mode, enter existing Shop Name Number (Ex. 1) to be deleted. OPER
SM – 100 Operation Manual 67 3.10 Advertisement File Advertisement message is the sales promotional description on the label, such as “FOR BARBECUE
Table of Content 1. GENERAL INFORMATION ...1 1.1 Overall View ...
SM – 100 Operation Manual 68 3.10.2 Delete Advertisement File At Advertisement programming mode, enter existing Advertisement Number (Ex. 1) to be
SM – 100 Operation Manual 69 3.11 Vender File Vender file is used for programming names of operators. Maximum 16 characters can be entered per Vend
SM – 100 Operation Manual 70 3.12 Program Date And Time The built-in clock system can automatically work once they are set. Date (Month/Day/Year):
SM – 100 Operation Manual 71 3.13 Special Message File Special Message can be used as a description on the label such as receipt, which can be assi
SM – 100 Operation Manual 72 3.13.2 Delete Special Message File At Special Message programming mode, enter existing Special Message Number (Ex. 1)
SM – 100 Operation Manual 73 3.14 Ingredient File Ingredients data programmed in this Master Ingredient file can be printed on the Free Format (F1-
SM – 100 Operation Manual 74 3.14.2 Delete Ingredient File At Ingredient programming mode, enter existing Ingredient Number (Ex. 1) to be deleted.
SM – 100 Operation Manual 75 3.15 Text File Maximum 20 Texts are available (Text 1~16 are for Item label and text 17~20 are for Total label). Text
SM – 100 Operation Manual 76 3.15.2 Delete Text File At Text programming mode, enter existing Text Number (Ex. 1) to be deleted. OPERATION DISPLAY
SM – 100 Operation Manual 77 3.16 Free Format File The Free Format enables you to design your own label format, by setting print angles, print posi
3.5 Program / Skip Item Data ... 45 3.6 PL
SM – 100 Operation Manual 78 3.16.2 Print Area, Print Position and Print Angles All changeable item data should be programmed 8mm above the bottom
SM – 100 Operation Manual 79 Print Position The printing position of each item data is decided by setting the distance from 0 point (X=0, Y=0) to t
SM – 100 Operation Manual 80 3.16.3 Programming Parameter Of Print Items Print Item for Item Label Up to 82 different item data can be programmed in
SM – 100 Operation Manual 81 Print Item for Total Label Up to 28 different item data can be programmed in Total Label Format and is used for printi
SM – 100 Operation Manual 82 3.16.4 Free Format Entry At Programming Mode, select Free Format programming mode and then enter new Free Format numb
SM – 100 Operation Manual 83 Base Type 1: Item data in Data Base Type1 are Numeric data or Fixed data. The print position of item data can be progr
SM – 100 Operation Manual 84 Base Type 2 Item data in Base Type 2 are Alpha-numeric data. The print position of item data can be programmed by sett
SM – 100 Operation Manual 85 Base Type 3 Item data in Data Base 3 is Barcode data. The print position of bar-code data can be programmed by setting
SM – 100 Operation Manual 86 Base Type 4 Item data in Data Base 4 is Frame data. The print position of Frame data may be programmed by setting X val
SM – 100 Operation Manual 87 3.16.5 Free Format Copy Function At Free Format programming mode, Select Copy existing Label Format and then select th
Komentáře k této Příručce