Digi Counting Version 4.0 DC-190 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Váhy Digi Counting Version 4.0 DC-190. Digi Counting Version 4.0 DC-190 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Installation Manual

74634 DC-190 ULTRA COUNT Counting Scale Version 4.0 Installation Manual

Strany 2 - 1.0 Introduction

Installation 92.5 Installing Cable Strain ReliefTo prevent load cell or peripheral cable damage frombending and twisting, cable strain reliefs are use

Strany 3

12 DC-190 Ultra Count Installation Manual3.0 Scale SetupThis section provides information about attaching scales and serial devices to the DC-190. Inf

Strany 4

Scale Setup 13• The scale attached to Port 2 is configured as External Scale.• All Scales (1–4) must be configured, and the value of each bit pair must

Strany 5 - 1.4 DC-190 Console

18 DC-190 Ultra Count Installation Manual4.2 Customer Specification (141 Settings)To configure customer specifications, press and hold the REZERO key and

Strany 6 - 1.4.2 DC-190 Keypad

Configuration Settings 197 0000 Setpoint Buzzer0: Yes1: NoSetpoint Latch0: Latching1: Non-latchingSetpoint Type00: % Quantity 01: % Weight10: Quantity

Strany 7 - 2.0 Installation

20 DC-190 Ultra Count Installation Manual15 0011 RS-232C Stop Bits (Barcode pen)0: 1 Bit1: 2 BitsRS-232C with Header (Barcode pen)0: Yes (first charact

Strany 8 - 2.3 Powering Up the DC-190

Configuration Settings 214.3 Weight and Measurement Specifications (142 Settings)To configure weight and measurement specifications, press and hold the

Strany 9 - TERMINAL

22 DC-190 Ultra Count Installation Manual27 0100 Comma Display0:No1:YesKeypad Entry of Tare0: No1: YesTare Range00: 100% FS 01: 50% FS10: 5% FS 11: No

Strany 10

Configuration Settings 2335 0000 Not used A/D Output (PORT 1, Scale 2)0: For std/normal load cell (≤ 18 mV)1: For abnormal load cell with too large of

Strany 11 - 3.0 Scale Setup

24 DC-190 Ultra Count Installation Manual4.4 RS-232 Specifications (143 Settings)To configure RS-232 specifications, press and hold the REZERO key and e

Strany 12

Introduction 1 About This Manual This manual contains operating procedures for the DC-190 counting scale and provides the user with all theinformatio

Strany 13

26 DC-190 Ultra Count Installation Manual6.0 Scale OperationsThe following sections contain detailed operator instructions for the DC-190 counting sca

Strany 14 - * key (printer and PC)

Scale Operations 276.2 Toggle Between ScalesTo switch the displays from Scale 1 through Scale 4, press the SCALE key when in weighing mode. Only scale

Strany 15 - – Key in Add Mode

28 DC-190 Ultra Count Installation Manual6.4.2 Unit Weight Operation by Key EntryUnit weight operation by key entry is accomplished by using the numer

Strany 16 - 142 access code

Scale Operations 29illuminated and the display shows the quantity of parts remaining.6. Remove a number of parts from the container and press the – ke

Strany 17

30 DC-190 Ultra Count Installation Manual7.0 Scale Programming7.1 Item Code StorageCode numbers allow you to store information for the parts that are

Strany 18 - Digital Tare with Weight

Scale Programming 317.2 Item Code MaintenanceItem code maintenance includes viewing item codes in memory and deleting item memory.View Item Codes in M

Strany 19

32 DC-190 Ultra Count Installation ManualNOTE: When you hear the beep, the display shows the last item code in memory. Press the – key to review theit

Strany 20 - 6.0 Scale Operations

Scale Programming 33Re-Computing Item Code Unit Weight1. Recall item code from memory (see Section or Section ). 2. Place items to be counted on the

Strany 21 - 6.4 Entering Unit Weights

34 DC-190 Ultra Count Installation Manual7.4 Global Setpoint Programming– Setpoints Not Tied to an Item Code The DC-190 provides the flexibility to use

Strany 22

52 DC-190 Ultra Count Installation Manual10.3 Connector PinoutsThe DC-190 provides CTS/RTS hardware handshaking lines on both the 8-pin DIN and 9-pin

Strany 23 - 6.6 Other Operations

2 DC-190 Ultra Count Installation Manual 1.1 Unpacking and Inspection Immediately after unpacking, visually inspect the DC-190 Ultra Count to ensure

Strany 24 - 7.0 Scale Programming

56 DC-190 Ultra Count Installation Manual10.6 DC-190 MessagesMessage ContentsACC Accuracy---Add XX Sampling quantity is insufficientALL All memoryC X

Strany 25 - 7.2 Item Code Maintenance

Appendix 5710.7 Clearing Locked-Up Scale (888888 Error)Several configuration errors can result in the scale locking up with a display that shows all 88

Strany 26

62 DC-190 Ultra Count Installation Manual10.11 DC-190 Ultra Count SpecificationsPowerPower source 100–120VAC or 220–240 VAC at 50/60 HzPower consumptio

Strany 27

Appendix 63DC-190 Ultra Count Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by aDi

Strany 28

Introduction 3 ModelCapacity (lb) Weighing Resolution (lb) Internal Resolution (lb) Platform DimensionsS-SL-50 50 0.005 0.00005 13” x 17”S-SL-100 100

Strany 29 - 10.3 Connector Pinouts

4 DC-190 Ultra Count Installation Manual 1.4 DC-190 Console Figure 1-1 shows the DC-190 console with annunciators and numeric keypad. Annunciators ar

Strany 30 - 10.6 DC-190 Messages

Introduction 5 1.4.2 DC-190 Keypad Table 1-5 lists the keys and key functions of the DC-190 Ultra Count keypad (see Figure 1-1 on page 4). KeyDescrip

Strany 31

6 DC-190 Ultra Count Installation Manual 2.0 Installation This section describes the procedure for theinstallation and setup of the DC-190 counting s

Strany 32

Installation 7 2.3 Powering Up the DC-190The DC-190 can be operated either from an AC powersource or with an optional rechargeable battery pack(DC po

Strany 33 - Appendix 63

8 DC-190 Ultra Count Installation Manual5. Place scale on side. Remove four top coverscrews (shown in Figure 2-7). Set scale onlegs and remove top cov

Komentáře k této Příručce

Žádné komentáře