74634 DC-190 ULTRA COUNT Counting Scale Version 4.0 Installation Manual
Installation 92.5 Installing Cable Strain ReliefTo prevent load cell or peripheral cable damage frombending and twisting, cable strain reliefs are use
12 DC-190 Ultra Count Installation Manual3.0 Scale SetupThis section provides information about attaching scales and serial devices to the DC-190. Inf
Scale Setup 13• The scale attached to Port 2 is configured as External Scale.• All Scales (1–4) must be configured, and the value of each bit pair must
18 DC-190 Ultra Count Installation Manual4.2 Customer Specification (141 Settings)To configure customer specifications, press and hold the REZERO key and
Configuration Settings 197 0000 Setpoint Buzzer0: Yes1: NoSetpoint Latch0: Latching1: Non-latchingSetpoint Type00: % Quantity 01: % Weight10: Quantity
20 DC-190 Ultra Count Installation Manual15 0011 RS-232C Stop Bits (Barcode pen)0: 1 Bit1: 2 BitsRS-232C with Header (Barcode pen)0: Yes (first charact
Configuration Settings 214.3 Weight and Measurement Specifications (142 Settings)To configure weight and measurement specifications, press and hold the
22 DC-190 Ultra Count Installation Manual27 0100 Comma Display0:No1:YesKeypad Entry of Tare0: No1: YesTare Range00: 100% FS 01: 50% FS10: 5% FS 11: No
Configuration Settings 2335 0000 Not used A/D Output (PORT 1, Scale 2)0: For std/normal load cell (≤ 18 mV)1: For abnormal load cell with too large of
24 DC-190 Ultra Count Installation Manual4.4 RS-232 Specifications (143 Settings)To configure RS-232 specifications, press and hold the REZERO key and e
Introduction 1 About This Manual This manual contains operating procedures for the DC-190 counting scale and provides the user with all theinformatio
26 DC-190 Ultra Count Installation Manual6.0 Scale OperationsThe following sections contain detailed operator instructions for the DC-190 counting sca
Scale Operations 276.2 Toggle Between ScalesTo switch the displays from Scale 1 through Scale 4, press the SCALE key when in weighing mode. Only scale
28 DC-190 Ultra Count Installation Manual6.4.2 Unit Weight Operation by Key EntryUnit weight operation by key entry is accomplished by using the numer
Scale Operations 29illuminated and the display shows the quantity of parts remaining.6. Remove a number of parts from the container and press the – ke
30 DC-190 Ultra Count Installation Manual7.0 Scale Programming7.1 Item Code StorageCode numbers allow you to store information for the parts that are
Scale Programming 317.2 Item Code MaintenanceItem code maintenance includes viewing item codes in memory and deleting item memory.View Item Codes in M
32 DC-190 Ultra Count Installation ManualNOTE: When you hear the beep, the display shows the last item code in memory. Press the – key to review theit
Scale Programming 33Re-Computing Item Code Unit Weight1. Recall item code from memory (see Section or Section ). 2. Place items to be counted on the
34 DC-190 Ultra Count Installation Manual7.4 Global Setpoint Programming– Setpoints Not Tied to an Item Code The DC-190 provides the flexibility to use
52 DC-190 Ultra Count Installation Manual10.3 Connector PinoutsThe DC-190 provides CTS/RTS hardware handshaking lines on both the 8-pin DIN and 9-pin
2 DC-190 Ultra Count Installation Manual 1.1 Unpacking and Inspection Immediately after unpacking, visually inspect the DC-190 Ultra Count to ensure
56 DC-190 Ultra Count Installation Manual10.6 DC-190 MessagesMessage ContentsACC Accuracy---Add XX Sampling quantity is insufficientALL All memoryC X
Appendix 5710.7 Clearing Locked-Up Scale (888888 Error)Several configuration errors can result in the scale locking up with a display that shows all 88
62 DC-190 Ultra Count Installation Manual10.11 DC-190 Ultra Count SpecificationsPowerPower source 100–120VAC or 220–240 VAC at 50/60 HzPower consumptio
Appendix 63DC-190 Ultra Count Limited WarrantyRice Lake Weighing Systems (RLWS) warrants that all RLWS equipment and systems properly installed by aDi
Introduction 3 ModelCapacity (lb) Weighing Resolution (lb) Internal Resolution (lb) Platform DimensionsS-SL-50 50 0.005 0.00005 13” x 17”S-SL-100 100
4 DC-190 Ultra Count Installation Manual 1.4 DC-190 Console Figure 1-1 shows the DC-190 console with annunciators and numeric keypad. Annunciators ar
Introduction 5 1.4.2 DC-190 Keypad Table 1-5 lists the keys and key functions of the DC-190 Ultra Count keypad (see Figure 1-1 on page 4). KeyDescrip
6 DC-190 Ultra Count Installation Manual 2.0 Installation This section describes the procedure for theinstallation and setup of the DC-190 counting s
Installation 7 2.3 Powering Up the DC-190The DC-190 can be operated either from an AC powersource or with an optional rechargeable battery pack(DC po
8 DC-190 Ultra Count Installation Manual5. Place scale on side. Remove four top coverscrews (shown in Figure 2-7). Set scale onlegs and remove top cov