PCI timing
www.digi.com
61
PCI timing
PCI AC characteristics are measured with 10pF, unless otherwise noted.
Table 30 and Table 31 describe the values shown in the PCI timing diagrams.
Notes:
1 Parameters same for bussed and point-to-point signals.
2 C
LOAD
= 10pf on all outputs
3 pci_clk_out high and low times specified as 50% of the clock period ±1 ns.
Parameter Description Min Max Units Notes
P1 pci_clk_in to signal valid delay 2 9 ns 1, 2
P2 input setup to pci_clk_in 5 ns 1
P3 input hold from pci_clk_in 0 ns
P4 pci_clk_in to signal active 2 ns 2
P5 pci_clk_in to signal float 28 ns 2
P6 pci_clk_out high time 50%-1 50%+1 ns 3
P7 pci_clk_out low time 50%-1 50%+1 ns 3
P8 pci_clk_in cycle time 30 ns
P9 pci_clk_in high time 11 ns
P10 pci_clk_in low time 11 ns
Table 30: PCI timing characteristics